To adjust the lighting intensity of all of
the instruments in the system, press and
hold both the “Down” and “Up” buttons
for 2 seconds. The lighting intensity may
now be adjusted by using the “Down” or
“Up” buttons.
Return to the Normalmode by pressing
and holding both the Down” and Up”
buttons for 2 seconds.
Displayed Functions
Tachometer
The tachometer is a digital instrument with
the appearance of an analog instrument.
The tachometer receives data directly
from the ECU so no settings are required
for the dial range. A microprocessor
controlled stepper motor moves the
pointer to display engine revolutions per
minute.
Default Screen “1”
Volts
Displays system voltage as received
from the ECU (Engine Control Unit).
OIL PRESSURE
Analog input. Displays information from
the analog oil pressure sender.
Default Screen “2”
Fuel Left
Displays the quantity of fuel remaining
in the fuel tank based on the original
quantity of fuel in the tank when full and
the amount of fuel used based on the
GPH from the engine ECU and the time
spent at each GPH. Fuel tank size and
reset are available in the “Edit” mode.
Fuel Used
Displays the amount of fuel used since
reset based on the GPH from the engine
ECU and the time spent at each GPH.
Fuel Inst
Displays the current, instantaneous, fuel
flow in GPH.
Default Screen “3”
Engine Temp
Displays the coolant temperature
received from the ECU. Dial range can
be selected in the “Edit” function.
Engine Hours